Earth leakage recloser - 2P - 40A - 30mA - typeA Acti9 RED

Brand: SCHNEIDER ELECTRIC

Reference: A9CR1240

Offer: £213.49
PVP: £408.41
£213.49
  • Quantity
  • Taxes included

Description

This Acti9 RED is a differential recloser (RCCB) It is a 2P circuit breaker with a rated current of 40A In, earth leakage sensitivity of 30mA and type A protection class This product protects against electric shock by direct or indirect contact and fire hazards Disconnects from live electrical circuits already protected against overloads and short circuits. Automatically restarts after monitoring of the isolated circuit.


Features

Number of modules:
2

Details

More information
Characteristics of the differential recloser - 2P - 40A - 30mA - typeA Acti9 RED:
- Type of product or component: Differential switch (RCCB)
- Short name of the device: RED
- Type of protection: Recloser ( 4 cycles)
- Number of poles: 2P
- Neutral position: Left
- [In] Nominal current: 40 A
- Earthing system:
TN-S< br>TT
- Type of network: AC
- Earth leakage sensitivity: 30 mA
- Location of the device in the system: Output
- Network frequency: 50 Hz
- [Ue] Nominal operating voltage: 230 V AC 50 Hz phase to neutral
- Reset: Earth leakage fault reset
- Test function: Manual at >, 100 V
- Protection delay against earth leakage: Instantaneous
- Class of protection against earth leakage: Type A
- Leakage resistance:
16 kOhm when operating
8 kOhm when not operating
- Closing capacity and nominal breaking current: Idm 630 A 230 V
- Short-circuit conditional current:
DPN, state 1 Inc 6 kA
DPNN, state 1 Inc 6 kA
IC60N, state 1 Inc 10 kA< br>IC60H, state 1 Inc 10 kA
IC60L, state 1 Inc 10 kA
IC60N, state 1 Inc 6 kA
IC60H, state 1 Inc 6 kA
IC60L, state 1 Inc 6 kA< br>NG125, state 1 Inc 10 kA
NG125, state 1 Inc 6 kA
Fuse, state 1 Inc 10 kA gG
Fuse, state 1 Inc 6 kA gG
- [Ui] Rated voltage insulation: 500 V
- [Uimp] Resistance to voltage spikes: 4 kV
- Type of control: Handle
- Local signaling:
1 green/red LED
Differential device : signaling ON/OFF
Recloser: signaling ON/OFF
- Operating mode:
Reclosing time: 10 s
Maximum operational frequency: 30/hour
Max nb of consecutive restart: 3
Min interval between 2 closings: 180 s
Insulation fault presence monitoring
Stopping restart cycle if insulation fault present
Restart in event of transient insulation fault
- Insulation fault diagnosis: If fault detected, diagnosis stopped
- Mounting type: Fixed
- Mounting bracket: 35 mm symmetrical DIN rail
- 9mm steps: 6
- Height: 106mm
- Width: 54mm
- Depth: 82mm
- Product weight: 278g
- Colour: Grey
- Mechanical durability: 4000 open-close cycles
- Connections - terminals:
Terminal with 35 mm² rigid cover< br>Terminal with cover 35 mm² flexible
Terminal with cover 35 mm² flexible with terminal
- Length of stripped wire to connect terminals: 12 mm
- Tightening torque: 3 N.m

Comments

There are no opinions yet Be the first to review!

Questions

No questions yet Do you have any doubt?

Best price

Have you seen it cheaper?
×

Our customers trust us

4.53/5 (2365 votes)

Opinions of our clients


Receive our news

See details + -
By checking this option we will send you the best offers and exclusive promotions and discounts to your email address. You can unsubscribe at any time.
Set your cookies preferences
We use cookies and similar technologies to offer you a personalized, safe, reliable experience and to be able to measure page performance to continue improving our services. For more information or to edit your cookie preferences at any time, check the Cookies policy page
Go out