More informationThese contactors are made for use in domestic applications as well as in industrial settings.
They are provided with the following benefits, hum-free operation, low power consumption, and built-in surge protection.
25A installation contactor characteristics:
- Nominal operating voltage:
Main circuit 220 V DC
Main circuit 400 V AC
- Nominal voltage of the control circuit (U c): 230 ... 240 V
- Nominal frequency (f):
Control circuit 400 Hz
Control circuit 50 Hz
Control circuit 60 Hz
DC control circuit
Main circuit 50 Hz
Main circuit 60 Hz
DC main circuit
- Rated operating current AC-1 (I e): (NO) 25 A
- Nominal operating current AC-3 (I e):
(230 V) Single phase, NO 9 A
(400 V) Three-phase, NO 9 A
- Rated operating power AC-1 (P e):
(230 V) Single phase, NO 5.8 kW
(400 V) Three-phase, NO 17.3 kW
- Nominal operating power AC-3 (P e):
(230 V) Single phase, NO 1.3 kW
(400 V) Three-phase, NO 4 kW
- Nominal operating current AC-7a (I e): (NO) 25 A
- Nominal operating power AC-7a (P e):
(230 V) Single phase, NO 5.8 kW
(400 V) Three-phase, NO 17.3 kW
- Nominal operating current AC-7b (I e):
(230 V) Single phase, NO 9 A
(400 V) Three-phase, NO 9 A
- Nominal operating power AC-7b (P e):
(230 V) Single phase, NO 1.3 kW
(400 V) Three-phase, NO 4 kW
- Recommended screwdriver:
Pozidriv 1 control circuit
Pozidriv 1 Main Circuit
- Nominal impulse withstand voltage (U imp): 6 kV
- Nominal insulation voltage (U i): 500 V
- Main circuit of connection capacity:
Flexible with sleeve 1x 1.5 ... 10 mm²
Flexible with sleeve 2x 1.5 ... 2.5 mm²
Flexible with insulated sleeve 1x 1.5 ... 10 mm²
Flexible with insulated bushing 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1,5. .. 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
- Connection of the capacity control circuit:
Flexible with sleeve 1x 1 ... 2.5 mm²
Flexible with sleeve 2x 0.75 ... 1 mm²
Flexible with insulated sleeve 1x 1 ... 2.5 mm²
Flexible with insulated ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
- Torque:
Control circuit 0.9 Nm
Main circuit 1 Nm
- Cable stripping length:
Control circuit 7 mm
Main circuit 10 mm
- Degree of protection: IP20
- Electrical durability:
AC-1 (NO) 130000 cycles
AC-3 (NO) 500000 cycles
AC-7a (NO) 130000 cycles
AC-7b (NO) 500000 cycles
- Mechanical durability: 1000000 cycle
- Number of poles: 4
- Number of main NC contacts: 0
- Number of main NO contacts: 4
- Width in number of modular spaces: 2
- Pollution degree: 3
- Standards:
IEC / EN 60947-1
IEC / EN 60947-4-1
IEC / EN 61095
UL 60947-1
UL 60947-4-1
Llegó en el tiempo previsto, el material era el correcto y su funcionamiento perfecto. Su precio muy bien, satisfecho de la compra.
Bom contator..
How do reviews and ratings work?
The opinions and ratings of the products are mostly made by registered customers who have purchased the product. These reviews appear with a "verified purchase" mark. In any other case this mark does not appear. The rating of the product, out of 5 stars, is obtained with the average of all published reviews of the product. To ensure that the information is useful to other customers, comments and ratings, whether positive or negative, they are published after prior validation.