More informationMain characteristics of the motion detector with inverted relay:
- Motion detector, with PIR technology, for surface mounting on the ceiling.
- It has 1 output channel with a 16A relay, free of voltage, and normally contact closed.
- Reverse operating logic: turns off the lighting when movement is detected.
- A second timing allows lighting to be activated once movement is no longer detected and the set delay time has elapsed.
>- Maximum coverage of 360º and Ø7m, at a height of 2.5m.
- Zero crossing switching, which allows the protection of your relay and high power switching.
- Valid for all types of lamps, including LED and UV lamps.
- Application example: control of germicidal lamps for the disinfection of rooms or rooms.
Technical characteristics of the motion detector with inverted relay:
- Supply voltage Power supply: 230V
- Frequency: 50Hz
- Own Consumption o: <,1W
- Output Channels: 1
- Relay breaking capacity: 16A
- LED lamps: 400W
- Incandescent and Halogen 230V: 3000W
- Halogen 12V with electronic transformer: 3000W
- Halogen lamps with ferromagnetic transformer: 2400W
- Voltage-free contact: Yes
- Detection angle: 360º
- Mounting height: 2.5m
- Diameter of detection: 7m
- Detection length: 0m
- Maximum number of extra motion sensors: 0
- Minimum time delay (seconds) T1 (detection delay): 1min / T2 (activation delay): 5min ~ 90min or cancelled
- Technology: PIR
- Mounting: Surface on ceiling
- Fluorescent lamps (VA): 1,300W
- Supports contactor: Yes
- Zero crossing: Yes
- Operating temperature (min): -10ºC
- Operating temperature (max): 45ºC
- Environmental protection: IP40
- According to directives: Low Voltage 2014/35/EU , Electromagnetic Compatibility 2014/30/EU, 2011/65/EU, RoHS 2011/65/EU
- In accordance with N Standard: UNE-EN 60669-2-1:2005, +erratum:2008, +/A1:2010, +/A12:2011, UNE-EN 60669-2-3:2007