Contactor Tesys D - 3 pole 440 V 9 A - 230 V AC coil Schneider electric

Brand: SCHNEIDER ELECTRIC

Reference: LC1D09P7

Offer: £34.72
PVP: £74.96
£34.72
  • Quantity
  • In stock. Immediate shipment.
    Taxes included

Description

Tesys D contactor - 3 poles, 440 volts and 9 amps - 230 V AC coil of the Schneider electric brand. Application of resistive load contactor.


Features

Number of modules:
3

Details

More information
Features of the Tesys D Contactor - 3 pole 440 V 9 A - 230 V AC coil:
- Range: TeSys
- Product name: TeSys D
- Product or component type: Connector
- Device short name: LC1D
- Contactor application:
Resistive load
Engine control
- Job category:
AC-4
AC-1
AC-3
- Number of poles: 3P
- Power pole contact composition: 3 NA
- [Ue] Nominal employment voltage:
Power circuit, state 1 <, = 690 V AC 25 ... 400 Hz
Power circuit, state 1 <, = 300 V DC
- [Ie] Nominal operating current:
9 at 60 ° C) at <, = 440 V AC AC-3 for power circuit
25 to 60 ° C) at <, = 440 V AC AC-1 for power circuit
- Engine power in kW
2.2 kW at 220 ... 230 V AC 50/60 Hz - cable type: AC-3)
4 kW at 380 ... 400 V AC 50/60 Hz - cable type: AC-3)
4 kW at 415 ... 440 V AC 50/60 Hz - cable type: AC-3)
5.5 kW at 500 V AC 50/60 Hz - cable type: AC-3)
5.5 kW at 660 ... 690 V AC 50/60 Hz - cable type: AC-3)
2.2 kW at 400 V AC 50/60 Hz - cable type: AC-4)
- Motor power HP (UL / CSA)
1 hp at 230/240 V AC 50/60 Hz for 1 motor phase
2 hp at 200/208 V AC 50/60 Hz for 3 phase motor
2 hp at 230/240 V AC 50/60 Hz for 3 phase motor
5 hp at 460/480 V AC 50/60 Hz for 3 phase motor
7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motor
0.33 hp at 115 V AC 50/60 Hz for 1 motor phase
- Control circuit type: AC at 50/60 Hz
- [Uc] control circuit voltage: 230 V AC 50/60 Hz
- Composition of auxiliary contacts: 1 NO + 1 NC
- [Uimp] Resistance to voltage peaks: 6 kV conforming to IEC 60947
- Overvoltage category: III
- [Ith] Conventional thermal current:
25 A at <.60 ° C for power circuit
10 A at <.60 ° C for signaling circuit
- Irms nominal connection power:
250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signaling circuit conforming to IEC 60947-5-1
250 A DC for signaling circuit conforming to IEC 60947-5-1
Assigned breaking power
250 A at 440 V for power circuit conforming to IEC 60947
- [Icw] Allowable time current:
105 A at <, 40 ° C - 10 s for power circuit
210 A at <.40 ° C - 1 s for power circuit
30 A at <.40 ° C - 10 min for power circuit
61 A at <.40 ° C - 1 min for power circuit
100 A - 1 s for signaling circuit
120 A - 500 ms for signaling circuit
140 A - 100 ms for signaling circuit
- Associated fuse:
10 A gG for signaling circuit conforming to IEC 60947-5-1
25 A gG at <, = 690 V coordination type 1 for power circuit
20 A gG at <, = 690 V type 2 coordination for power circuit
- Average impedance: 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- [Ui] Nominal insulation voltage:
Power circuit, status 1 690 V conforming to IEC 60947-4-1
Power circuit, status 1 600 V CSA certified
Power circuit, status 1 600 V UL certified
Signaling circuit, status 1 690 V conforming to IEC 60947-1
Signaling circuit, status 1 600 V CSA certified
Signaling circuit, status 1 600 V UL certified
- Electrical durability:
0.6 Mcycles 25 A AC-1 at Ue <, = 440 V
2 Cycles 9 A AC-3 in Ue <, = 440 V
- Power dissipated per pole
1.56 W AC-1
0.2 W AC-3
- Front cover: With
- Mounting bracket
Lane
License plate
- Rules:
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
- Product certifications:
GOST
BV
LROS (Lloyds Register of Shipping)
DNV
CSA
FIGHT
CCC
UL
GL
- Connection type:
Power circuit, status 1 Screw terminals 1 cable (s) 1… 4 mm² Flexible without cable end
Power circuit, status 1 Screw terminals 2 cable (s) 1… 4 mm² Flexible without cable end
Power circuit, status 1 Screw terminals 1 cable (s) 1… 4 mm² Flexible with
Power circuit, status 1 Screw terminals 2 cable (s) 1… 2.5 mm² Flexible with
Power circuit, status 1 Screw terminals 1 cable (s) 1… 4 mm² solid without cable end
Power circuit, status 1 Screw terminals 2 cable (s) 1… 4 mm² solid without cable end
Control circuit, status 1 Screw terminals 1 cable (s) 1… 4 mm² Flexible without cable end
Control circuit, status 1 Screw terminals 2 cable (s) 1… 4 mm² Flexible without cable end
Control circuit, status 1 Screw terminals 1 cable (s) 1… 4 mm² Flexible with
Control circuit, status 1 Screw terminals 2 cable (s) 1… 2.5 mm² Flexible with
Control circuit, status 1 Screw terminals 1 cable (s) 1… 4 mm² solid without cable end
Control circuit, status 1 Screw terminals 2 cable (s) 1… 4 mm² solid without cable end
- Torque:
Power circuit, state 1 1.7 Nm - on screw terminals - with flat screwdriver Ø 6
Power circuit, state 1 1.7 Nm - on screw terminals - with Philips screwdriver nº 2
Control circuit, state 1 1.7 Nm - on screw terminals - with flat screwdriver Ø 6
Control circuit, state 1 1.7 Nm - in Screw terminals - with Philips screwdriver nº 2
Maneuver duration
12 ... 22 ms closing
4 ... 19 ms opening
- Security reliability level:
B10d = 1369863 contactor cycles with nominal load conforming to EN / ISO 13849-1
B10d = 20,000,000 contactor cycles with mechanical load according to EN / ISO 13849-1
- Mechanical durability:
15 Mcycles
- Operation range:
3600 cyc / h at <.60 ° C

Videos (2)

Comments

There are no opinions yet Be the first to review!

Questions

No questions yet Do you have any doubt?

Best price

Have you seen it cheaper?
×

Our customers trust us

4.53/5 (2362 votes)

Opinions of our clients


Receive our news

See details + -
By checking this option we will send you the best offers and exclusive promotions and discounts to your email address. You can unsubscribe at any time.
Set your cookies preferences
We use cookies and similar technologies to offer you a personalized, safe, reliable experience and to be able to measure page performance to continue improving our services. For more information or to edit your cookie preferences at any time, check the Cookies policy page
Go out