More informationCharacteristics of the TeSys D contactor - 3 poles (3 NO):
- Range: TeSys
Product Name: TeSys D
Product or component type: Connector
Device short name: LC1D
- Contactor application:
Engine control
Resistive load
- Job category:
AC-4
AC-1
AC-3
- Number of poles: 3P
- Power pole contact composition: 3 NA
- [Ue] Nominal operating voltage:
Power circuit: <, = 690 V AC 25 ... 400 Hz
Power circuit: <, = 300 V DC
- [Ie] Nominal operating current
9 at 60 ° C) at <, = 440 V AC AC-3 for power circuit
25 A 60 ° C) at <, = 440 V AC AC-1 for power circuit
- Motor power in kW:
2.2 kW at 220 ... 230 V AC 50/60 Hz - cable type: AC-3)
4 kW at 380 ... 400 V AC 50/60 Hz - cable type: AC-3)
4 kW at 415 ... 440 V AC 50/60 Hz - cable type: AC-3)
5.5 kW at 500 V AC 50/60 Hz - cable type: AC-3)
5.5 kW at 660 ... 690 V AC 50/60 Hz - cable type: AC-3)
2.2 kW at 400 V AC 50/60 Hz - cable type: AC-4)
- Motor power HP (UL / CSA):
1 hp at 230/240 V AC 50/60 Hz for 1 phase motor
2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
- Control circuit type: DC Standard
- [Uc] control circuit voltage: 24 V DC
- Composition of the auxiliary contacts: 1 NO + 1 NC
- [Uimp] Resistance to voltage spikes: 6 kV conforming to IEC 60947
- Overvoltage category: III
- [Ith] Conventional thermal current:
25 A at <.60 ° C for power circuit
10 A at <.60 ° C for signaling circuit
- Irms rated connection power:
250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signaling circuit conforming to IEC 60947-5-1
250 A DC for signaling circuit conforming to IEC 60947-5-1
- Rated breaking capacity: 250 A at 440 V for power circuit conforming to IEC 60947
- [Icw] Allowable temporary current:
105 A at <.40 ° C - 10 s for power circuit
210 A at <.40 ° C - 1 s for power circuit
30 A at <.40 ° C - 10 min for power circuit
61 A at <.40 ° C - 1 min for power circuit
100 A - 1 s for signaling circuit
120 A - 500 ms for signaling circuit
140 A - 100 ms for signaling circuit
- Associated fuse:
10 A gG for signaling circuit conforming to IEC 60947-5-1
25 A gG at <, = 690 V coordination type 1 for power circuit
20 A gG at <, = 690 V coordination type 2 for power circuit
- Average impedance: 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- [Ui] Rated insulation voltage:
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signaling circuit: 690 V conforming to IEC 60947-1
Signaling circuit: 600 V CSA certified
Signaling circuit: 600 V UL certified
- Electrical durability:
0.6 Mcycles 25 A AC-1 at Ue <, = 440 V
2 Mcycles 9 A AC-3 at Ue <, = 440 V
- Power dissipated per pole:
1.56 W AC-1
0.2 W AC-3
- Front cover: With
- Mounting bracket:
License plate
Lane
- Rules
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
- Product certifications:
LROS (Lloyds Register of Shipping)
CSA
UL
GOST
DNV
CCC
GL
BV
FIGHT
- Connection type:
Power circuit: Screw terminals 1 cable (s) 1… 4 mm²Flexible without cable end
Power circuit: screw clamp terminals 2 cable (s) 1… 4 mm²flexible without cable end
Power circuit: Screw terminals 1 cable (s) 1… 4 mm²Flexible with
Power circuit: Screw clamp terminals 2 cable (s) 1… 2.5 mm² Flexible with
Power circuit: Screw terminals 1 cable (s) 1… 4 mm² solid without cable end
Power circuit: screw clamp terminals 2 cable (s) 1… 4 mm² solid without cable end
Control circuit: Screw terminals 1 cable (s) 1… 4 mm²Flexible without cable end
Control circuit: screw clamp terminals 2 cable (s) 1… 4 mm²flexible without cable end
Control circuit: Screw terminals 1 cable (s) 1… 4 mm²Flexible with
Control circuit: Screw clamp terminals 2 cable (s) 1… 2.5 mm² Flexible with
Control circuit: screw terminals 1 cable (s) 1… 4 mm² solid without cable end
Control circuit: screw terminals 2 cable (s) 1… 4 mm² solid without cable end
- Torque:
Power circuit: 1.7 Nm - on Screw terminals - with Ø 6 flat screwdriver
Power circuit: 1.7 Nm - on Screw terminals - with Philips # 2 screwdriver
Control circuit: 1.7 Nm - on Screw terminals - with Ø 6 flat screwdriver
Control circuit: 1.7 Nm - on Screw terminals - with # 2 Philips screwdriver
- Duration of maneuver:
53.55 ... 72.45 ms closing
16 ... 24 ms opening
- Security reliability level:
B10d = 1369863 contactor cycles with nominal load conforming to EN / ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN / ISO 13849-1
- Mechanical durability: 30 Mcycles
- Operating range: 3600 cyc / h at <.60 ° C