Rehabilitaweb your online provider of air conditioning, plumbing and electricity.
Send to:
Send to:
Take advantage of the best Pre-Black Friday discounts at Rehabilitaweb
Subscribe 💌 CLICK HERE and we give you an ADDITIONAL 5€ DISCOUNT on your first purchase *Minimum order €100

TeSys D contactor - 3 poles (3 NO) Schneider electric

Brand: SCHNEIDER ELECTRIC

Reference: LC1D09BD

Offer: £67.73
PVP: £146.20
£67.73

Description

Contactor of the TeSys D range - 3 poles (3 NO) of the Schneider electric brand. - For motor control and resistive load applications.


Features

Number of modules:
3

Details

More information
Characteristics of the TeSys D contactor - 3 poles (3 NO):
- Range: TeSys
Product Name: TeSys D
Product or component type: Connector
Device short name: LC1D
- Contactor application:
Engine control
Resistive load
- Job category:
AC-4
AC-1
AC-3
- Number of poles: 3P
- Power pole contact composition: 3 NA
- [Ue] Nominal operating voltage:
Power circuit: <, = 690 V AC 25 ... 400 Hz
Power circuit: <, = 300 V DC
- [Ie] Nominal operating current
9 at 60 ° C) at <, = 440 V AC AC-3 for power circuit
25 A 60 ° C) at <, = 440 V AC AC-1 for power circuit
- Motor power in kW:
2.2 kW at 220 ... 230 V AC 50/60 Hz - cable type: AC-3)
4 kW at 380 ... 400 V AC 50/60 Hz - cable type: AC-3)
4 kW at 415 ... 440 V AC 50/60 Hz - cable type: AC-3)
5.5 kW at 500 V AC 50/60 Hz - cable type: AC-3)
5.5 kW at 660 ... 690 V AC 50/60 Hz - cable type: AC-3)
2.2 kW at 400 V AC 50/60 Hz - cable type: AC-4)
- Motor power HP (UL / CSA):
1 hp at 230/240 V AC 50/60 Hz for 1 phase motor
2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
- Control circuit type: DC Standard
- [Uc] control circuit voltage: 24 V DC
- Composition of the auxiliary contacts: 1 NO + 1 NC
- [Uimp] Resistance to voltage spikes: 6 kV conforming to IEC 60947
- Overvoltage category: III
- [Ith] Conventional thermal current:
25 A at <.60 ° C for power circuit
10 A at <.60 ° C for signaling circuit
- Irms rated connection power:
250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signaling circuit conforming to IEC 60947-5-1
250 A DC for signaling circuit conforming to IEC 60947-5-1
- Rated breaking capacity: 250 A at 440 V for power circuit conforming to IEC 60947
- [Icw] Allowable temporary current:
105 A at <.40 ° C - 10 s for power circuit
210 A at <.40 ° C - 1 s for power circuit
30 A at <.40 ° C - 10 min for power circuit
61 A at <.40 ° C - 1 min for power circuit
100 A - 1 s for signaling circuit
120 A - 500 ms for signaling circuit
140 A - 100 ms for signaling circuit
- Associated fuse:
10 A gG for signaling circuit conforming to IEC 60947-5-1
25 A gG at <, = 690 V coordination type 1 for power circuit
20 A gG at <, = 690 V coordination type 2 for power circuit
- Average impedance: 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- [Ui] Rated insulation voltage:
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signaling circuit: 690 V conforming to IEC 60947-1
Signaling circuit: 600 V CSA certified
Signaling circuit: 600 V UL certified
- Electrical durability:
0.6 Mcycles 25 A AC-1 at Ue <, = 440 V
2 Mcycles 9 A AC-3 at Ue <, = 440 V
- Power dissipated per pole:
1.56 W AC-1
0.2 W AC-3
- Front cover: With
- Mounting bracket:
License plate
Lane
- Rules
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
- Product certifications:
LROS (Lloyds Register of Shipping)
CSA
UL
GOST
DNV
CCC
GL
BV
FIGHT
- Connection type:
Power circuit: Screw terminals 1 cable (s) 1… 4 mm²Flexible without cable end
Power circuit: screw clamp terminals 2 cable (s) 1… 4 mm²flexible without cable end
Power circuit: Screw terminals 1 cable (s) 1… 4 mm²Flexible with
Power circuit: Screw clamp terminals 2 cable (s) 1… 2.5 mm² Flexible with
Power circuit: Screw terminals 1 cable (s) 1… 4 mm² solid without cable end
Power circuit: screw clamp terminals 2 cable (s) 1… 4 mm² solid without cable end
Control circuit: Screw terminals 1 cable (s) 1… 4 mm²Flexible without cable end
Control circuit: screw clamp terminals 2 cable (s) 1… 4 mm²flexible without cable end
Control circuit: Screw terminals 1 cable (s) 1… 4 mm²Flexible with
Control circuit: Screw clamp terminals 2 cable (s) 1… 2.5 mm² Flexible with
Control circuit: screw terminals 1 cable (s) 1… 4 mm² solid without cable end
Control circuit: screw terminals 2 cable (s) 1… 4 mm² solid without cable end
- Torque:
Power circuit: 1.7 Nm - on Screw terminals - with Ø 6 flat screwdriver
Power circuit: 1.7 Nm - on Screw terminals - with Philips # 2 screwdriver
Control circuit: 1.7 Nm - on Screw terminals - with Ø 6 flat screwdriver
Control circuit: 1.7 Nm - on Screw terminals - with # 2 Philips screwdriver
- Duration of maneuver:
53.55 ... 72.45 ms closing
16 ... 24 ms opening
- Security reliability level:
B10d = 1369863 contactor cycles with nominal load conforming to EN / ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN / ISO 13849-1
- Mechanical durability: 30 Mcycles
- Operating range: 3600 cyc / h at <.60 ° C

Comments

There are no opinions yet Be the first to review!

Questions

No questions yet Do you have any doubt?

Best price

Have you seen it cheaper?
×

Our customers trust us

4.53/5 (2278 votes)

Opinions of our clients


Receive our news

See details + -
By checking this option we will send you the best offers and exclusive promotions and discounts to your email address. You can unsubscribe at any time.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Set your cookies preferences
We use cookies and similar technologies to offer you a personalized, safe, reliable experience and to be able to measure page performance to continue improving our services. For more information or to edit your cookie preferences at any time, check the Cookies policy page
Go out